Radium-228 – Non-Potable Water
Group: Radiochemistry
Procedure #: EZZ0153A
CPT: N/A
| Synonym(s): | Ra-228 in Non-Potable Water |
|---|---|
| Requisition Form | G-22 |
| Test Description | The determination of Ra-228 in non-potable water samples. |
| Pre-Approval Needed | N/A |
| Supplemental Information Required | N/A |
| Supplemental Form(s) | N/A |
| Performed on Specimens from (sources) | Environmental |
| Sample/Specimen Type for Testing | Non-potable water |
| Minimum Volume/Size Required | Hard or soft plastic; 1 gallon |
| Storage/Preservation Prior to Shipping | None - Sample must be submitted to the laboratory within 5 days of collection. |
| Transport Medium | N/A |
| Specimen Labeling | Label each bottle with a water proof marker. Pre-printing labels is acceptable. Sample identification must match submission form. |
| Shipping and Specimen Handling Requirements | Sample must be submitted to the laboratory within 5 days of collection. |
| Method | SM 7500-RaD |
| Turn-around Time | Hold time for non-potable water samples is unregulated but the target sample turnaround time is 90 days from date of receipt. |
| Interferences/Limitations | N/A |
| Common Causes for Rejection |
|
| Additional Information |